We have over 35 years of great success building our maintenance-free flange motors. The built-in cylindrical roller bearings with high load capacity and increased bearing life are lubricated with a special grease for life. The possibility errors associated with a dirty grease nipple, incorrect amount of grease being added or incorrect re-greasing is ruled out. By using our maintenance-free Flange motor you will reduce your maintenance costs.

General specifications

 

FRIEDRICH Vibrator Motor flange

FF Type 50 Hz

 

4 pole vibrator motors (1460 min-1)

friedrich ff type 50 hz

TYPE

Working-

moment

[kg cm]

Centrifugal force

[N]

 

Power 

consumption

[kW]

Nominal current at 460 V

[A]

Power factor

[COS ∅]

Starting current ratio

[IA/IN] 

 

Pitch

Circle

Maße

Dimensions

Cotesmm 

Weight

[kg]

Cable

[mm]

Screw

8.8

a b c d e f
FF 150-4-2.1 150 17500 1,0 2,28 082 6,6

305

315

355

6x->22

8x->14

540 20 231 95 78 4x1,5

M20

M12

FF 200-4-2.1 200 23400 1,0 2,28 0,82 6,6

305

315

355

6x->22

8x->14

610 20 231 116 83 4x1,5

M20

M12

 
FF 340-4-4.1 340 39700 3,0 5,89 0,87 7,8

315

520

380

570

8x->22

16x->18

528 25  175 135

135

 142

4x1,5

M20

M16

 
FF 400-4-4.1 400 46800 3,0 5,89 0,87 7,8 315

520

380

570

8x->22

16x->18

562 25 192 135

146

153

4x1,5

M20

M16

 
FF 550-4-7.1 550 64200 7,0 15,20 0,86 7,6 420 480  15x->18 730 25 315 140 255 4x2,5 M16
FF 700-4-7.1 700 81800 7,0 15,20 0,86 7,6 420 480 15x->18 730 25 315 152 285 4x2,5 M16
FF 800-4-7.1 800 93600 7,0 15,20 0,86 7,6 420 480 15x->18 774 25 337 152 292 4x2,5 M16

6 pole vibrator motors (980 min-1)

friedrich ff type 50 hz

TYPE

Working-

moment

[kg cm]

Centrifugal force

[N]

 

Power 

consumption

[kW]

Nominal current at 460 V

[A]

Power factor

[COS ∅]

Starting current ratio

[IA/IN] 

 

Pitch

Circle

Maße

Dimensions

Cotesmm 

Weight

[kg]

Cable

[mm]

Screw

8.8

a b c d e f
FF 150-6-2.1  150 7900 0,75 1,62  0,70 5,3 305

315

355 6x->22

8x->14

540  20  231 95 78  4x1,5

M20

M12

FF 200-6-2.1  200 10600 0,75 1,62 0,70  5,3 305

315

355 6x->22

8x->14

590  20 256 95 83 4x1,5 

M20

M12

 
 FF 250-6-2.1 250 13200 0,75 1,62 0,70 5,3 305

315

355 6x->22

8x->14

540  20 231 116 90 4x1,5

M20

M12

 FF 300-6-2.1 300 15800 0,75 1,62 0,70 5,3 305

315

355 6x->22

8x->14

540  20 231  115 94 4x1,5

M20

M12

 FF 550-6-4.2 550 29000 2,70 6,18 0,80 6,6

315

320

 380

570

8x->22

16x->18

669  25 245  133

160

167

4x1,5  

M20

M16

 FF 680-6-4.2 680 35800 2,70 6,18 0,80 6,6

315

320

 

380

570

8x->22

16x->18

668  25 245 133

169

176

4x1,5

M20

M16

 FF 750-6-4.2 750 39750  2,70 6,18 0,80 6,6

315

320

380

570

8x->22

16x->18

 712 25  267 133

187

194

4x1,5  M20

M16

 FF 1000-6-7.1 1000 52600 4,0 8,27 0,84 7,5 420 480 15x->18  810 25 355 152 280  4x1,5 M16 
FF 1300-6-7.1  1300 68400 4,0 8,27 0,84 7,5 420 480 15x->18 900   25 400 152 194 4x1,5 M16 
 FF 2500-6-9.0 2500 132500 8,0 18,34 0,70  9,5 550 610 26 894  30 407  198 570 4x2,5 M24

 

General specifications

Power Supply:
Voltages from 115 V to 690 V at 50 Hz and 60 Hz available.

Degree of protection:
IP 54

Thermal class:
F (155 °C) according to DIN EN 60034-1

Tropical insulation:
standard

Electrical connection:
Use high flexible cable for heavy mechanical stress, for Example: H07RN-F or A07RN-F according to DIN VDE 0282.

Permissible ambient temperature:
-30 to +40 °C

Operating mode:
Continuous operation (S1) and discontinuous operation at 100 % centrifugal force.

Assembly:
Without limitation, motors can be mounted in any position.

Color coating:
By default, in 6011. Other RAL colors available on request.

Type code:

  • The numbers indicate the maximum working moment in kgcm
    (working moment = 2 x Static moment),
  • This is followed by a hyphen and then the pole number,
  • Where: 4 = 1460 rpm 6 = 980 rpm (at 50 Hz mains frequency).